2 Parameters
2.2 List of parameters
SINAMICS DCM
178 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays additional information about the active alarm for float values.
Dependency: Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146, r3121, r3123
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description: Display and BICO output for the second status word of faults and alarms.
Description: Display and BICO output for the second status word of faults and alarms.
Description: Displays the system runtime in days when the fault was removed.
Dependency: Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2130, r2133, r3115, r3120, r3122
Notice: The time comprises r2136 (days) and r2109 (milliseconds).
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2134[0...63] Alarm value for float values / Alarm value float
All objects Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8065
P-Group: Messages Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r2135.0...2 CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2548
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fault encoder 1 Yes No -
01 Fault encoder 2 Yes No -
02 Fault encoder 3 Yes No -
r2135.0...15 CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S, TM150,
TM15DI_DO, TM31
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2548
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fault encoder 1 Yes No -
01 Fault encoder 2 Yes No -
02 Fault encoder 3 Yes No -
12 Fault motor overtemperature Yes No 8016
13 Fault power unit thermal overload Yes No 8014
14 Alarm motor overtemperature Yes No 8016
15 Alarm power unit thermal overload Yes No 8014
r2136[0...63] Fault time removed in days / t_flt resolv days
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: 8060
P-Group: Messages Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -