2 Parameters
2.1 Overview of parameters
SINAMICS DCM
22 List Manual (LH8), 02/2015, 6RX1800-0ED76
Parameter values
Not for motor type
This information is of no relevance for SINAMICS DC MASTER.
Scaling
Specification of the reference variable with which a signal value is automatically converted for
a BICO interconnection.
The following reference variables are available:
• p2000 ... p2007: Reference speed, reference voltage, etc.
• PERCENT: 1.0 = 100 %
• 4000H: 4000 hex = 100 %
Expert list
Specifies whether this parameter is available in the expert list of the specified drive objects in
the commissioning software.
1: Parameter is available in the expert list.
0: Parameter is not available in the expert list.
Min. Minimum value of the parameter [unit]
Max Maximum value of the parameter [unit]
Factory setting Value when delivered [unit]
In the case of a binector/connector input, the signal source of the
default BICO interconnection is specified. A non-indexed
connector output is assigned the index [0].
NOTICE
Users are responsible for using parameters that are marked "Expert list: 0" (parameter not
included in the expert list).
These parameters and their functionalities have not been tested and no further user
documentation is available for them (e.g. description of functions). Moreover,
"Technical Support" (hotline) does not provide any support for these parameters.