SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
597
2 Parameters
2.2 List of parameters
Description: Display and connector output for the armature current controller adaptation.
Dependency: Refer to: p50572, p50573, p50574
Description: Display and connector output for the field current controller adaptation.
Dependency: Refer to: p50577, p50578
Description: Connector output for fixed value 1 set in p50401.
Dependency: Refer to: p50401
Description: Connector output for fixed value 2 set in p50402.
Dependency: Refer to: p50402
Description: Connector output for fixed value 3 set in p50403.
Dependency: Refer to: p50403
r52350 CO: Adaptation armature current control output / Adapt Ia_ctrl outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6853
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52355 CO: Adaptation field current control output / Adapt If_ctrl outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6908
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52401 CO: Fixed value 1 / Fix val 1
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3100
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52402 CO: Fixed value 2 / Fix val 2
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3100
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52403 CO: Fixed value 3 / Fix val 3
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3100
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]