EasyManua.ls Logo

Siemens SINAMICS DCM - Absolute Encoder Linear Measuring Step Resolution; Enc Abs Meas Step; Absolute Encoder Rotary Multiturn Resolution; Enc Abs Multiturn; Absolute Encoder Rotary Singleturn Resolution; Enc Abs Singleturn; Encoder Linear Zero Mark Distance; Enc Lin Zm_Dist

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
70 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the number of rotations that can be resolved for a rotary absolute encoder.
Notice: This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Description: Sets the resolution of the absolute position for a linear absolute encoder.
Notice: This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note: The serial protocol of an absolute encoder provides the position with a certain resolution , e.g. 100 nm. This value
must be entered here.
Description: Sets the number of measuring steps per revolution for a rotary absolute encoder.
The resolution refers to the absolute position.
Notice: This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description: Sets the distance between two zero marks for a linear encoder.
This information is used for zero mark monitoring.
Bit field: Bit Signal name 1 signal 0 signal FP
00 SUB-D Yes No -
01 Terminal Yes No -
p0421[0...n] Absolute encoder rotary multiturn resolution / Enc abs multiturn
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: 4704
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 4096
p0422[0...n] Absolute encoder linear measuring step resolution / Enc abs meas step
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: 4704
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [nm] 4294967295 [nm] 100 [nm]
p0423[0...n] Absolute encoder rotary singleturn resolution / Enc abs singleturn
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: 4704
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1073741823 8192
p0424[0...n] Encoder linear zero mark distance / Enc lin ZM_dist
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [mm] 65535 [mm] 20 [mm]