SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
635
2 Parameters
2.2 List of parameters
Description: Display and connector output/binector output for the state of the device fan.
Dependency: Refer to: p50082, p50096
Refer to: F60167
Note: Dependent upon the order number (MLFB), the fan configuration may be as follows:
- No fans
- 2 DC fans
- 1 AC fan
Re bits 8 ... 11:
These bits are not effective on the Control Module.
Re bit 12:
This bit is only effective on the Control Module.
Description: Displays the integrated device fan.
Note: For the Control Module, fan "available" is always displayed as the Control Module only has one output to control the
fan.
The display is independent of the state of the fan and only indicates the desired state.
Description: Display and connector output of the state of the fan and external fault for the Control Module.
r53135.0...12 CO/BO: Device fan state / Dev fan state
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Switch on fan ON OFF 8047
01 Switch on fan inverted ON OFF 8047
08 Fan 1 speed OK Yes No (too low) 8047
09 Fan 2 speed OK Yes No (too low) 8047
10 Fan 3 speed OK Yes No (too low) 8047
11 Fan 4 speed OK Yes No (too low) 8047
12 Control Module fan speed OK Yes No 8049
r53136 Device fan present / Device_fan pres
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DC fan 1 Available Not present 6960
01 DC fan 2 Available Not present 6960
02 AC fan 1 Available Not present 6960
03 AC fan 2 Available Not present 6960
04 Control Module fan Available Not present 6960
r53140.0...4 CO/BO: Fan and external fault / Fan ext F
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 8049
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals