2 Parameters
2.2 List of parameters
SINAMICS DCM
476 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the x coordinate for pair of values 1 for adaptation of the droop.
Notice: The following condition applies for x coordinate 1/2:
p50558 < p50561
Note: The adaptation of the droop is defined using 2 pairs of values.
Pair of values 1:
p50558/p50552 (x/y coordinate)
Pair of values 2:
p50561/p50227 (x/y coordinate)
Description: Sets the x coordinate for pair of values 2 for adaptation of the P gain (Kp).
Notice: The following condition applies for x coordinate 1/2:
p50556 < p50559
Note: The adaptation of the P gain (Kp) is defined using 2 pairs of values.
Pair of values 1:
p50556/p50550 (x/y coordinate)
Pair of values 2:
p50559/p50225 (x/y coordinate)
Description: Sets the x coordinate for pair of values 2 for adaptation of the integral time (Tn).
Notice: The following condition applies for x coordinate 1/2:
p50557 < p50560
Note: The adaptation of the integral time (Tn) is defined using 2 pairs of values.
Pair of values 1:
p50557/p50551 (x/y coordinate)
Pair of values 2:
p50560/p50226 (x/y coordinate)
p50558[0...3] Speed controller adaptation droop x coordinate 1 / Adapt droop x1
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6805
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 0.00 [%]
p50559[0...n] Speed controller adaptation Kp x coordinate 2 / Adapt Kp x2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6805
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 0.00 [%]
p50560[0...n] Speed controller adaptation Tn x coordinate 2 / Adapt Tn x2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6805
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 0.00 [%]