2 Parameters
2.2 List of parameters
SINAMICS DCM
596 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for the current actual values of the cabinet devices with power units connected in
parallel.
Only active for 6RM80 with options Z04, Z05, Z07, Z13 and Z15
Index: [0] = Power unit 1
[1] = Power unit 2
Description: Display and connector output for the thyristor temperature rise of the cabinet devices with power units connected in
parallel.
Index: [0] = Power unit 1
[1] = Power unit 2
Note: This parameter is only active for 6RM80 devices with options Z04, Z05, Z07, Z13 and Z15.
Description: Display and connector output for the field line frequency.
The value is a percentage of 50 Hz.
Description: Display and connector output of the counter EMF ratio EMF/V_line.
Dependency: Refer to: r52122, r52305
r52311[0...1] CO: Current actual value of the parallel power units / Ia par_power_unit
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8042
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52312[0...1] CO: I2T thyristor temperature rise of the parallel power units / I2T par_power unit
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8042
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52316 CO: Field line frequency / Field f_line
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52320 CO: Armature current control counter EMF ratio / V_counter_ratio
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -