EasyManua.ls Logo

Siemens SINAMICS DCM - BI: Signal Source for Switching on Line Contactor; Line Cont on Sig S; E Stop Response; E Stop Response; LOCAL Mode Enable Behavior; LOCAL Enab Behav; Setpoint Processing Reduction Factor; Red Factor

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
536 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the reduction factor for the speed setpoint in the context of setpoint processing.
Dependency: Dependent upon binector input (p51607):
1 signal:
The reduction factor (p51608) is not applied (r52194 = r52195).
0 signal:
The reduction factor (p51608) is applied (r52194 = r52195 x p51608).
Refer to: p51607, r52194, r52195
Description: Sets the response of the control to the triggering of an E stop.
Value: 0: E stop has the same effect as OFF2
1: E stop triggers immediate pulse inhibit
Note: If value = 0:
E stop has the same effect as OFF2.
If value = 1:
E stop interrupts the firing pulse sequence immediately. The process does not wait for Ia = 0 and Alpha W pulses are
not emitted.
Description: Sets the behavior for enable via terminal X177.13 in the LOCAL mode.
Value: 0: Terminal X177.13 is not effective in the LOCAL mode
1: Terminal X177.13 is effective in the LOCAL mode
Description: Sets the signal source for the "Line contactor ON" relay output (XR1.109/110).
p51608[0...n] Setpoint processing reduction factor / Red factor
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 15.00 [%]
p51616 E stop response / E stop response
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2070
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p51618 LOCAL mode enable behavior / LOCAL enab behav
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2580
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p51619[0...n] BI: Signal source for switching on line contactor / Line cont ON sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 2070
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 53081.0

Table of Contents

Other manuals for Siemens SINAMICS DCM

Related product manuals