2 Parameters
2.2 List of parameters
SINAMICS DCM
536 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the reduction factor for the speed setpoint in the context of setpoint processing.
Dependency: Dependent upon binector input (p51607):
1 signal:
The reduction factor (p51608) is not applied (r52194 = r52195).
0 signal:
The reduction factor (p51608) is applied (r52194 = r52195 x p51608).
Refer to: p51607, r52194, r52195
Description: Sets the response of the control to the triggering of an E stop.
Value: 0: E stop has the same effect as OFF2
1: E stop triggers immediate pulse inhibit
Note: If value = 0:
E stop has the same effect as OFF2.
If value = 1:
E stop interrupts the firing pulse sequence immediately. The process does not wait for Ia = 0 and Alpha W pulses are
not emitted.
Description: Sets the behavior for enable via terminal X177.13 in the LOCAL mode.
Value: 0: Terminal X177.13 is not effective in the LOCAL mode
1: Terminal X177.13 is effective in the LOCAL mode
Description: Sets the signal source for the "Line contactor ON" relay output (XR1.109/110).
p51608[0...n] Setpoint processing reduction factor / Red factor
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 100.00 [%] 15.00 [%]
p51616 E stop response / E stop response
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2070
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p51618 LOCAL mode enable behavior / LOCAL enab behav
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2580
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p51619[0...n] BI: Signal source for switching on line contactor / Line cont ON sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 2070
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 53081.0