2 Parameters
2.2 List of parameters
SINAMICS DCM
530 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting to invert the individual binector inputs of the binector connector converter.
Dependency: Refer to: p51117, r52620
Note: BI: Binector Input
Description: Displays the software version for the Converter Commutation Protector (CCP).
Index 0: CCP software version
Index 1: Version of the CCP boot sector software
Description: Displays the serial number of the Converter Commutation Protector (CCP).
Note: The individual digits of the number are displayed in ASCII code in the indices.
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
p51118 Invert binector-connector converter signals / Bin/con sig inv
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 BI p51117[0] Inverted Not inverted -
01 BI p51117[1] Inverted Not inverted -
02 BI p51117[2] Inverted Not inverted -
03 BI p51117[3] Inverted Not inverted -
04 BI p51117[4] Inverted Not inverted -
05 BI p51117[5] Inverted Not inverted -
06 BI p51117[6] Inverted Not inverted -
07 BI p51117[7] Inverted Not inverted -
08 BI p51117[8] Inverted Not inverted -
09 BI p51117[9] Inverted Not inverted -
10 BI p51117[10] Inverted Not inverted -
11 BI p51117[11] Inverted Not inverted -
12 BI p51117[12] Inverted Not inverted -
13 BI p51117[13] Inverted Not inverted -
14 BI p51117[14] Inverted Not inverted -
15 BI p51117[15] Inverted Not inverted -
r51560[0...1] CCP software version / CCP SW version
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6970
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r51569[0...15] CCP serial number / CCP ser no.
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: 6970
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -