2 Parameters
2.2 List of parameters
SINAMICS DCM
584 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for the sum of all jog setpoints (p50436[0 to 7]).
Dependency: Refer to: p50435, p50436
Description: Display and connector output for the square-wave generator.
Dependency: Refer to: p50480, p50481, p50482, p50483
Description: Display and connector output for the sum of all fixed setpoints (p50431[0 to 7]).
Dependency: Refer to: p50430, p50431
Description: Display and connector output of the setpoint dependent upon creep.
Description: Display and connector output of the setpoint dependent upon jog.
r52202 CO: Jog setpoint output / Jog set outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52203 CO: Oscillation square-wave generator setpoint / Oscill sq-w gen
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3120
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52204 CO: Fixed setpoint output / Fix set outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3115
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52206 CO: Creep setpoint output after selection / Cr set outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52207 CO: Jog setpoint output after selection / Jog set outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]