2 Parameters
2.2 List of parameters
Description: Sets the rated armature voltage as indicated on the motor's nameplate.
This parameter is used, for example, to specify the trigger point in field weakening operation.
Note: If a significant voltage drop is to be expected at the motor's supply line when the motor is at rated current (e.g. very
long motor cable), a value increased by this voltage drop should be set at p50101.
Description: Sets the rated excitation current as indicated on the motor's nameplate.
Note: If p50102 = 0.00 A, the drive cannot be switched on and put into operation.
Description: Sets the minimum excitation current for the motor.
Description: Sets speed n1 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets speed n1 for the first pair of values (p50104/p50105).
Dependency: Refer to: p50105, p50106, p50107, p50108, p50109
Note: The following condition applies:
p50104 <= p50106 (n1 <= n2)
p50101[0...n] Motor rated armature voltage / Mot rated V_armat
DC_CTRL Can be changed: C2(1), T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
10 [V] 2800 [V] 400 [V]
p50102[0...n] Motor rated excitation current / Mot rated I_exc
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [A] 600.00 [A] 0.00 [A]
p50103[0...n] Minimum motor excitation current / Mot I_exc min
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [A] 600.00 [A] 0.00 [A]
p50104[0...n] Speed-dependent current limitation speed n1 / I_lim n_dep n1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 [1 rpm] 10000 [1 rpm] 5000 [1 rpm]