2 Parameters
2.2 List of parameters
SINAMICS DCM
292 List Manual (LH8), 02/2015, 6RX1800-0ED76
Dependency: Refer to: p7764
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: Configuration settings for know-how protection.
Re bit 00, 01:
When KHP is activated, this means that the OEM can define whether the parameters and DCC data encrypted on the
memory card should be protected before using on other memory cards/Control Units.
Re bit 02:
This means that the OEM can define whether it is possible or not to trace the drive data using the device trace
function although KHP is activated.
Dependency: Refer to: p7766, p7767, p7768
p7764[0...n] KHP OEM exception list / KHP OEM excep list
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: p7763 Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 [0] 7766
[1...499] 0
p7764[0...n] KHP OEM exception list / KHP OEM excep list
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S, TM150,
TM15DI_DO, TM31
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: p7763 Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 0
p7765 KHP configuration / KHP config
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Extended copy protection - linked to the
memory card and CU
Yes No -
01 Basic copy protection - linked to the
memory card
Yes No -
02 Permit trace and measuring functions for
diagnostic purposes
Yes No -