SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
283
2 Parameters
2.2 List of parameters
Dependency: Refer to: p4840, r4841
Description: Displays the number of OA applications installed on this drive object.
Dependency: Refer to: r4951, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note: DO: Drive Object
OA: Open Architecture (OA application)
Description: Displays the total length of the identifiers of the OA applications installed on this drive object.
Dependency: Refer to: r4950, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note: The identifier of an OA application comprises a maximum of 8 characters plus separator.
Description: Displays the total length of the GUIDs of the OA applications installed on this drive object.
Dependency: Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note: The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
Description: Displays the identifier of the OA applications installed on this drive object.
r4955[0...8]: Identifier of OA application 1
r4955[9...17]: Identifier of OA applications 2, ...
Dependency: Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
r4950 OA DO-specific number / OA DO qty
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 16 -
r4951 OA DO-specific identifier total length / OA DO id tot_lgth
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 144 -
r4952 OA DO-specific GUID total length / OA DO GUID length
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 288 -
r4955[0...n] OA DO-specific identifier / OA DO ident
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4951 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents