2 Parameters
2.2 List of parameters
SINAMICS DCM
594 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Load connection:
Display and connector output for the supplementary current setpoint.
Note: This is used to increase the dynamic response of the voltage control regarding disturbing variable changes when
using the SINAMICS DCM as I/R unit or supplying a DC busbar.
A supplementary current setpoint is input, which is calculated according to the following formula:
I_(set,suppl)=I_d-C*(dU_d)/dt
100 % corresponds to p50072[1]
Description: Display and connector output for the line voltage U-V in the armature circuit.
Description: Display and connector output for the line voltage V-W in the armature circuit.
Description: Display and connector output for the line voltage W-U in the armature circuit.
Description: Display and connector output for the line voltage in the field circuit.
r52298 CO: Load connection supplementary current setpoint output / Suppl Ia_set off
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52301 CO: Armature line voltage U-V / Arm V_line U-V
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52302 CO: Armature line voltage V-W / Arm V_line V-W
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52303 CO: Armature line voltage W-U / Arm V_line W-U
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52304 CO: Field line voltage / Field V_line
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6910, 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]