EasyManua.ls Logo

Siemens SINAMICS DCM - CO: Armature Line Voltage U-V; Arm V_Line U-V; CO: Armature Line Voltage V-W; Arm V_Line V-W; CO: Armature Line Voltage W-U; Arm V_Line W-U; CO: Load Connection Supplementary Current Setpoint Output

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
594 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Load connection:
Display and connector output for the supplementary current setpoint.
Note: This is used to increase the dynamic response of the voltage control regarding disturbing variable changes when
using the SINAMICS DCM as I/R unit or supplying a DC busbar.
A supplementary current setpoint is input, which is calculated according to the following formula:
I_(set,suppl)=I_d-C*(dU_d)/dt
100 % corresponds to p50072[1]
Description: Display and connector output for the line voltage U-V in the armature circuit.
Description: Display and connector output for the line voltage V-W in the armature circuit.
Description: Display and connector output for the line voltage W-U in the armature circuit.
Description: Display and connector output for the line voltage in the field circuit.
r52298 CO: Load connection supplementary current setpoint output / Suppl Ia_set off
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52301 CO: Armature line voltage U-V / Arm V_line U-V
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52302 CO: Armature line voltage V-W / Arm V_line V-W
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52303 CO: Armature line voltage W-U / Arm V_line W-U
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52304 CO: Field line voltage / Field V_line
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6910, 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]