2 Parameters
2.2 List of parameters
SINAMICS DCM
356 List Manual (LH8), 02/2015, 6RX1800-0ED76
Note: The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description: Displays the first index of the signal source being searched for.
Dependency: Refer to: r9481, r9482, r9483, p9484, r9485
Note: The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description: Displays the number of signal sources from this drive to other drives/drive objects (Binector Output/Connector
Output, BO/CO).
Dependency: Refer to: r9491, r9492, p9493
Description: Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency: Refer to: r9490, r9492, p9493
Notice: A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note: All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description: Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency: Refer to: r9490, r9491, p9493
Notice: A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
r9486 BICO interconnections signal source search first index / BICO S_src srchIdx
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r9490 Number of BICO interconnections to other drives / Qty BICO to drive
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9491[0...9] BI/CI of BICO interconnections to other drives / BI/CI to drive
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9492[0...9] BO/CO of BICO interconnections to other drives / BO/CO to drive
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -