2 Parameters
2.2 List of parameters
SINAMICS DCM
626 List Manual (LH8), 02/2015, 6RX1800-0ED76
Index: [0] = Armature current Ia
[1] = Field current If
[2] = Armature current Ia current transformer I
[3] = Armature current Ia current transformer II
Description: Display and connector output for the scan values of the thyristor blocking voltages.
Index: [0] = Blocking voltage thyristor X11
[1] = Blocking voltage thyristor X12
[2] = Blocking voltage thyristor X13
[3] = Blocking voltage thyristor X14
[4] = Blocking voltage thyristor X15
[5] = Blocking voltage thyristor X16
[6] = Blocking voltage thyristor X21
[7] = Blocking voltage thyristor X22
[8] = Blocking voltage thyristor X23
[9] = Blocking voltage thyristor X24
[10] = Blocking voltage thyristor X25
[11] = Blocking voltage thyristor X26
Description: Displays the deviation of the last point in time on the averaged time grid from the last point in time on an original time
grid (armature).
Description: Displays the deviation of the last point in time on the averaged time grid from the last point in time on an original time
grid (field).
Description: Displays the DC offset (= direct-current component) of the armature line phases in volts.
Index: [0] = Armature phase UV
[1] = Armature phase VW
r52953[0...11] CO: Thyristor blocking voltages scan values / V_thyr scan_values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52960 Armature line zero crossings deviation / Arm line zero dev
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [µs] - [µs] - [µs]
r52961 Field line zero crossings deviation / Field line zero dv
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [µs] - [µs] - [µs]
r52965[0...1] Line analysis armature line phase offset / Arm line ph offs
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]