SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
381
2 Parameters
2.2 List of parameters
Description: Displays the absolute value of the motor current setpoint.
Note: This parameter is referred to the rated motor current.
The following applies: 100% corresponds to p50100[ii], whereby ii = active DDS
Description: Displays the torque setpoint after limiting.
Note: 1 corresponds to 0.1% of the rated torque of the motor.
Description: Displays the torque setpoint before limiting.
Note: 1 corresponds to 0.1% of the rated torque of the motor.
Description: Display and connector output of the selected speed actual value on the speed controller.
Description: Displays the speed setpoint before the ramp-function generator.
Dependency: Refer to: r52193
r50020 Closed-loop armature current control motor current set abs value / Ia ctr I_set abs
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r50021 Torque limiting torque setpoint after limiting / Tqe set after lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6830
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r50022 Torque limiting torque setpoint before limiting / Tqe set bef lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6830
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r50025 Speed controller actual value selection / Act sel
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r50028 Speed setpoint before the ramp-function generator display / n_set bef RFG disp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [1 rpm] - [1 rpm] - [1 rpm]