2 Parameters
2.2 List of parameters
SINAMICS DCM
468 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the torque setpoint in slave mode.
Dependency: Refer to: p50503
Description: Sets the signal source for the torque additional setpoint in torque limiting.
The value is injected in addition to friction and moment of inertia compensation.
Description: Sets the signal source for the additional setpoint of the speed controller.
This value is added to the speed controller's output value.
Description: Sets the factor for the torque setpoint in slave mode.
Dependency: Refer to: p50500
Description: Sets the signal source for the speed actual value (n_act) on the speed limiting controller.
p50500[0...n] CI: Torque limiting signal source for t_set in slave mode / T_set s mode sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6830
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52170[0]
p50501[0...n] CI: Torque limiting signal source for torque additional setpoint / T_lim add s sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6830
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50502 CI: Speed controller additional setpoint signal source / Add set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50503[0...n] Torque limiting t_set factor in slave mode / T_set fact sl mode
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6830
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] 100.00 [%]
p50509 CI: Speed limiting controller signal source for speed actual value / n_lim n_act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]