2 Parameters
2.2 List of parameters
SINAMICS DCM
440 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the ramp-down time for ramp-function generator parameter set 3.
Description: Sets the initial rounding for ramp-function generator parameter set 3.
Dependency: Refer to: p50295
Description: Sets the final rounding for ramp-function generator parameter set 3.
Dependency: Refer to: p50295
Description: Displays the effective times on the ramp-function generator.
Index: [0] = Ramp-up time
[1] = Ramp-down time
[2] = Initial rounding
[3] = Final rounding
Description: Displays the state on the ramp-function generator.
p50312[0...n] RFG ramp-down time 3 / RFG t_ramp-dn 3
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 650.00 [s] 10.00 [s]
p50313[0...n] RFG initial rounding 3 / RFG init rndg 3
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]
p50314[0...n] RFG final rounding 3 / RFG fin rndg 3
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]
r50315[0...3] RFG effective times / RFG t effective
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [s] - [s] - [s]
r50316 RFG state / RFG state
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents