SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
595
2 Parameters
2.2 List of parameters
Description: Display and connector output for the average line voltage over the 3 phases in the armature circuit.
Description: Display and connector output for the line frequency in the armature circuit.
The value is a percentage of 50 Hz.
Description: Display and connector output for the average motor power supplied.
Dependency: Refer to: r52109, r52287
Description: Display and connector output for the calculated motor temperature rise.
Dependency: Refer to: p50114
Refer to: A60037, F60137
Description: Display and connector output for the calculated thyristor temperature rise as a percentage of the maximum
temperature.
r52305 CO: Average armature line voltage / Arm V_line avg
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950, 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52306 CO: Armature line frequency / Arm f_line
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855, 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52307 CO: Average motor power supplied / Mot P supp avg
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52309 CO: Calculated motor temperature rise / Calc mot temp rise
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8038
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52310 CO: I2t monitoring thyristor temperature rise / I2t thyr temp rise
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8042
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]