2 Parameters
2.2 List of parameters
SINAMICS DCM
576 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for acceleration dependent upon setpoint/actual value difference.
In the case of the "Acceleration dependent upon setpoint/actual value difference" function, only the proportion of the
speed controller's setpoint/actual value difference which has an absolute value in excess of the threshold (p50543) is
switched through.
Dependency: Refer to: p50541, p50543
Description: Display and connector output for the reference model for the speed controller.
Dependency: Refer to: p50237, p50238, p50239
Description: Display and connector output for the setpoint-actual value difference after the influence of the reference model for the
speed controller.
Dependency: Refer to: p50621, p50622, p50623, p50624
Description: Display and connector output for the output value of the lead/lag element.
Dependency: Refer to: p50207, p50208, p50209
Description: Display and connector output for the speed controller's output value.
r52152 CO: Speed controller setpoint/actual value difference output / Set/act dif outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6820
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52154 CO: Speed controller reference model output / n_ctrl ref outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6812
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52155 CO: Speed controller reference model setpoint-actual val difference / n_ctr ref set-act
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6812
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52156 CO: Lead/lag element output value / Lead/lag output
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52160 CO: Speed controller output value / n_ctr outp val
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]