SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
269
2 Parameters
2.2 List of parameters
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 0 and signal 2.
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 0 and signal 3.
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 0 and signal 4.
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 0 and signal 5.
Dependency: Refer to: r4760
Description: Displays the trace buffer (record buffer) for trace 0 and signal 6.
Dependency: Refer to: r4760
r4762[0...16383] Trace 0 trace buffer signal 2 / Trace 0 tr sig 2
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4763[0...16383] Trace 0 trace buffer signal 3 / Trace 0 tr sig 3
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4764[0...16383] Trace 0 trace buffer signal 4 / Trace 0 tr sig 4
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4765[0...16383] Trace 0 trace buffer signal 5 / Trace 0 tr sig 5
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4766[0...16383] Trace 0 trace buffer signal 6 / Trace 0 tr sig 6
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -