2 Parameters
2.2 List of parameters
Description: Display and connector output for the lower limit of the field current setpoint.
Dependency: Refer to: p50103, p50614
Description: Display and connector output for the field current setpoint after field current setpoint limiting.
Dependency: Refer to: p50611
Description: Display and connector output for the field current setpoint before field current setpoint limiting.
Dependency: Refer to: p50611
Description: Display and connector output from pre-control and EMF controller after selection.
If p50081 = 0:
--> r52277 = 100%
If p50081 = 1:
--> r52277 = Sum of EMF controller and EMF pre-control outputs
Dependency: Refer to: p50081
r52274 CO: Field current setpoint limiting lower limit output / If lim low lim
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52275 CO: Field current setpoint limiting output after limiting / If lim outp lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6905, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52276 CO: Field current setpoint limiting output before limiting / If lim outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52277 CO: EMF controller pre-control and controller output after selection /
EMF prec+ctrl sel
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]