2 Parameters
2.2 List of parameters
SINAMICS DCM
484 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the armature current actual value for closed-loop armature current control.
Description: Sets the signal source for the variable current limit in torque direction I.
Note: About [0 to 3]:
Selects which parameter is injected as the variable current limit in torque direction I.
Scaling: +100% corresponding to p50100 * p50171.
About [4]:
Selects which parameter is injected as the current limit in torque direction I for quick stop or shutdown.
Scaling: +100% corresponding to p50100 * p50171.
About [5]:
Selects which parameter is injected as the variable current limit in torque direction I.
Scaling: +100% corresponding to r50072[1].
About [6]:
Selects which parameter is injected as the current limit in torque direction I for quick stop or shutdown.
Scaling: +100% corresponding to r50072[1].
Description: Sets the signal source for the variable current limit in torque direction II.
Note: About [0 to 3]:
Selects which parameter is injected as the variable current limit in torque direction II.
Scaling: +100% corresponding to p50100 * p50171.
About [4]:
Selects which parameter is injected as the current limit in torque direction II for quick stop or shutdown.
Scaling: +100% corresponding to p50100 * p50171.
p50602 CI: Cl-loop arm current control sig source for arm current act val / Ia ctr Ia ac sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52117[0]
p50603[0...6] CI: Current limitation current limit torque direction I / I_lim I_lim t d I
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6840
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0...4] 1
[5] 52002[0]
[6] 52002[0]
p50604[0...6] CI: Current limitation current limit torque direction II / I_lim I_lim t d II
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6840
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0] 52135[0]
[1] 52135[1]
[2] 52135[2]
[3] 52135[3]
[4] 52135[4]
[5] 52135[5]
[6] 52135[6]