SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
287
2 Parameters
2.2 List of parameters
Description: Displays the number of OA applications installed on the memory card/device memory.
Dependency: Refer to: r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note: OA: Open Architecture (OA application)
Description: Displays the total length of the IDs of all the OA applications installed on the memory card/device memory.
Dependency: Refer to: r4985, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note: The identifier of an OA application comprises a maximum of 8 characters plus separator.
Description: Displays the total length of the GUIDs of all the OA applications installed on the memory card/device memory.
Dependency: Refer to: r4985, r4986, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note: The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
Description: Displays the IDs of all the OA applications installed on the memory card/device memory.
r4988[0...8]: Identifier of OA application 1
r4988[9...17]: Identifier of OA applications 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4989, r4990, r4991, r4992, r4993, r4994
Notice: If there is no OA application, then it is not possible to access an index.
r4985 OA number / OA no
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 16 -
r4986 OA identifier total length / OA id tot_length
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 144 -
r4987 OA GUID total length / OA GUID tot_length
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 288 -
r4988[0...n] OA identifier / OA ID
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4986 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -