2 Parameters
2.2 List of parameters
Description: Displays the trace buffer (record buffer) for trace 1 and signal 1.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 1 and signal 2.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 1 and signal 3.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 1 and signal 4.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 1 and signal 5.
Dependency: Refer to: r4740, p4795
r4751[0...16383] Trace 1 trace buffer signal 1 floating point / Trace 1 tr sig 1
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4752[0...16383] Trace 1 trace buffer signal 2 floating point / Trace 1 tr sig 2
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4753[0...16383] Trace 1 trace buffer signal 3 floating point / Trace 1 tr sig 3
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4754[0...16383] Trace 1 trace buffer signal 4 floating point / Trace 1 tr sig 4
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4755[0...16383] Trace 1 trace buffer signal 5 floating point / Trace 1 tr sig 5
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -