2 Parameters
2.2 List of parameters
Description: Displays the counter reading for internal errors.
Description: Displays the compensation values for the analog inputs/outputs on the Control Unit DC MASTER (CUD).
Note: Analog input 0 - X177.25/26 - voltage input
[0] = Compensation value at 0 V
[1] = Compensation value at +10 V
[2] = Compensation value at -10 V
[3] = Compensation value at reference value
Analog input 0 - X177.25/26 - current input
[4] = Compensation value at 0 mA
[5] = Compensation value at +20 mA
[6] = Compensation value at -20 mA
[7] = Compensation value at reference value
Analog input 1 - X177.27/28 - voltage input
[8] = Compensation value at 0 V
[9] = Compensation value at +10 V
[10] = Compensation value at -10 V
[11] = Compensation value at reference value
Analog input 1 - X177.27/28 - current input
[12] = Compensation value at 0 mA
[13] = Compensation value at +20 mA
[14] = Compensation value at -20 mA
[15] = Compensation value at reference value
Analog input 2 - X177.29/30
[16] = Compensation value at 0 V
[17] = Compensation value at +10 V
[18] = Compensation value at -10 V
[19] = Compensation value at reference value
Analog input XT1.103/104 - 25 V
[20] = Compensation value at 0 V
[21] = Compensation value at +25 V
[22] = Compensation value at -25 V
[23] = Compensation value at reference value
Analog input XT1.103/104 - 80 V
[24] = Compensation value at 0 V
[25] = Compensation value at +80 V
[26] = Compensation value at -80 V
[27] = Compensation value at reference value
r50827 Internal diagnostics / Int diag
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: 8060
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r50829[0...55] CUD compensation values / CUD calib. val
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: 8054
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -