SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
359
2 Parameters
2.2 List of parameters
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
Description: Displays the actual topology of the drive unit.
The actual topology is sub-divided into several sections. Each of the following data is saved under an index.
General data on the topology:
- version
- attribute to compare the actual topology and target topology
- number of components
Data on a component:
- type component of the node ID of the component
- number of DRIVE-CLiQ sockets in the Node Identifier
- manufacturer and version of the Node Identifier
- serial number of the Node Identifier (4 indices)
- index of the component
- order number (8 indices)
- attribute to compare the actual topology and target topology of the component
- communications address
- number of port types
- port type
- number of ports of the port type
- communications address of the associated/linked component
- number of the associated/linked port
- communications address of the associated/linked component
- number of the associated port, etc.
Data on the next component:
- etc.
Dependency: Refer to: r9900
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
Description: Sets the number of target topology indices.
Dependency: Refer to: p9903
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
r9901[0...n] Actual topology / Act topo
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: r9900 Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
p9902 Target topology number of indices / TargetTopo indices
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
1 65535 1