2 Parameters
2.2 List of parameters
SINAMICS DCM
588 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output of the field current controller's actual value.
Description: Displays the absolute value of the internal field current actual value as a percentage of p50073.01.
Description: Display and connector output of the field current controller's setpoint.
Description: Display and connector output of pre-control for closed-loop field current control.
Description: Display and connector output for the upper limit of the field current setpoint.
Dependency: Refer to: r50073, p50102, p50613
r52265 CO: Cl-loop field curr ctrl current controller actual value / If_ctr act
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6905, 6910,
8025, 8044
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52266 CO: Field current actual value internal absolute value / If_act int abs
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6912
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52268 CO: Closed-loop field current control current controller setpoint / If_ctr set
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6910, 8025,
8044
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52271 CO: Closed-loop field current control pre-control output / If_ctr prec outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52273 CO: Field current setpoint limiting upper limit output / If lim up lim
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]