2 Parameters
2.2 List of parameters
SINAMICS DCM
150 List Manual (LH8), 02/2015, 6RX1800-0ED76
[54] = PZD 55
[55] = PZD 56
[56] = PZD 57
[57] = PZD 58
[58] = PZD 59
[59] = PZD 60
[60] = PZD 61
[61] = PZD 62
[62] = PZD 63
[63] = PZD 64
Note: IF1: Interface 1
Value range:
0 - 242: Byte offset
65535: Not assigned
Description: Displays the PZD byte offset in the PROFIdrive send telegram (controller input).
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Note: IF1: Interface 1
Value range:
0 - 242: Byte offset
65535: Not assigned
Description: Displays the addresses of the slaves (peers) where peer-to-peer data transfer has been configured via PROFIBUS.
Description: Sets the send and receive telegram.
Contrary to p0922, a telegram can be selected using p2079 and subsequently expanded.
Value: 390: SIEMENS telegram 390, PZD-2/2
391: SIEMENS telegram 391, PZD-3/7
392: SIEMENS telegram 392, PZD-3/15
393: SIEMENS telegram 393, PZD-4/21
394: SIEMENS telegram 394, PZD-3/3
r2076[0...4] IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
TM150, TM15DI_DO,
TM31
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: 2410
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r2077[0...15] PROFIBUS diagnostics peer-to-peer data transfer addresses / PB diag peer addr
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p2079 IF1 PROFIdrive PZD telegram selection extended / IF1 PZD telegr ext
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
390 999 999