2 Parameters
2.2 List of parameters
SINAMICS DCM
312 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting for saving the actual configuration of the Advanced Operator Panel (AOP).
Description: Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency: Refer to: p0015
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency: Refer to: p0700
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency: Refer to: p1000
Note: For a value = 9999999, the following applies: The read operation is still running.
p8550 AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 1001 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 LOCAL save Yes No -
01 Start in LOCAL Yes No -
02 Change in oper Yes No -
03 OFF acts like OFF1 Yes No -
04 OFF acts like OFF2 Yes No -
05 OFF acts like OFF3 Yes No -
06 Reserved Yes No -
07 CW/CCW active Yes No -
08 Jog active Yes No -
09 Save speed setpoint Yes No -
14 Inhibit operation Yes No -
15 Inhibit parameterization Yes No -
r8570[0...39] Macro drive object / Macro DO
All objects Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r8571[0...39] Macro Binector Input (BI) / Macro BI
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r8572[0...39] Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -