4 Faults and alarms
4.1 Overview of faults and alarms
SINAMICS DCM
866 List Manual (LH8), 02/2015, 6RX1800-0ED76
Drive object:
Each message (fault/alarm) specifies the drive object in which it can be found.
A message can belong to either one, several, or all drive objects.
Reaction: Default fault reaction (adjustable fault reaction)
Specifies the default reaction in the event of a fault.
The optional parentheses indicate whether the default fault reactions can be changed and
which fault reactions can be adjusted via parameters (p2100, p2101).
Acknowledgment: Default acknowledgment (adjustable acknowledgment)
Specifies the default method of acknowledging faults after the cause has been eliminated.
The optional parentheses indicate whether the default acknowledgment can be changed and
which acknowledgment can be adjusted via parameters (p2126, p2127).
Error in the parameterization/configuration/commissioning
procedure (18)
An error was identified in the parameterization or in a commissioning
procedure, or the parameterization does not match the actual device
configuration. Determine the precise cause of the fault using the
commissioning tool. Adapt the parameterization or device
configuration.
9011 17 31 16 15
General drive fault (19)
Group fault. Determine the precise cause of the fault using the
commissioning tool.
9012 18 9 9 15
Auxiliary unit fault (20)
The monitoring of an auxiliary unit (incoming transformer, cooling
unit …) has detected an illegal state. Determine the exact cause of the
fault and check the relevant device.
9013 19 29 26 15
1. Undervoltage condition of the electronics power supply
2. Overvoltage condition of the electronics power supply
Table 4-4 Message classes and coding of various diagnostic interfaces, continued
Text of the message class (number according to PROFIdrive)
Cause and remedy.
Diagnostics interface
PN
(hex)
DS1
(dec)
DP
(dec)
ET 200
(dec)
NAMUR
(r3113.x)
Note
See Table "Fault reactions" (Page 859)
Note