SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
651
2 Parameters
2.3 Parameters for data sets
p50296[0...n] RFG quick stop (OFF3) ramp-down time / RFG OFF3 t_ramp-dn
p50297[0...n] RFG quick stop (OFF3) initial rounding / RFG OFF3 init rndg
p50298[0...n] RFG quick stop (OFF3) final rounding / RFG OFF3 fin rndg
p50300[0...n] RFG positive setpoint limit after ramp-function generator / RFG pos after RFG
p50301[0...n] RFG negative setpoint limit after ramp-function generator / RFG neg after RFG
p50302[0...n] RFG ramp-up integrator operating mode / RFG integ op mode
p50303[0...n] RFG ramp-up time 1 / RFG t_ramp-up 1
p50304[0...n] RFG ramp-down time 1 / RFG t_ramp-dn 1
p50305[0...n] RFG initial rounding 1 / RFG init rndg 1
p50306[0...n] RFG final rounding 1 / RFG fin rndg 1
p50307[0...n] RFG ramp-up time 2 / RFG t_ramp-up 2
p50308[0...n] RFG ramp-down time 2 / RFG ramp-dn time 2
p50309[0...n] RFG initial rounding 2 / RFG init rndg 2
p50310[0...n] RFG final rounding 2 / RFG fin rndg 2
p50311[0...n] RFG ramp-up time 3 / RFG t_ramp-up 3
p50312[0...n] RFG ramp-down time 3 / RFG t_ramp-dn 3
p50313[0...n] RFG initial rounding 3 / RFG init rndg 3
p50314[0...n] RFG final rounding 3 / RFG fin rndg 3
p50317[0...n] RFG tracking enable / RFG track ena
p50318[0...n] RFG setting value selection / RFG set val sel
p50319[0...n] RFG setpoint enable delay time / RFG set_ena i_del
p50320[0...n] Setpoint processing main setpoint factor / m_set_factor
p50321[0...n] Setpoint processing additional setpoint factor / Add_set_factor
p50330[0...n] RFG time unit / RFG time unit
p50351[0...n] Line undervoltage threshold / Line V_und thresh
p50352[0...n] Line overvoltage threshold / Line V_over thresh
p50353[0...n] Line monitoring phase failure threshold / Ph_fail thresh
p50355[0...n] Stall protection monitoring time / Stall t_mon
p50356[0...n] Stall protection threshold / Stall prot thresh
p50357[0...n] Tachometer interruption monitoring threshold / Tacho_mon thresh
p50361[0...n] Line monitoring undervoltage delay time / V_under t_del
p50362[0...n] Line monitoring overvoltage delay time / Line V_over t_del
p50363[0...n] Line frequency minimum threshold / f_line min thresh
p50364[0...n] Line frequency maximum threshold / f_line max thresh
p50370[0...n] Messages for speed less than minimum speed threshold / n < n_min thresh
p50371[0...n] Messages for speed less than minimum speed hysteresis / n < n_min hyst
p50372[0...n] Messages speed positive hysteresis / Msg n > 0 hyst
p50373[0...n] Messages for reference speed threshold / Ref_speed thresh
p50374[0...n] Messages for reference speed hysteresis / Ref_speed hyst
p50375[0...n] Messages for reference speed OFF delay / Ref_speed t_OFF
p50376[0...n] Messages for setpoint/actual value deviation 2 threshold / Set/act 2 thresh
p50377[0...n] Messages for setpoint/actual value deviation 2 hysteresis / Set/act 2 hyst
p50378[0...n] Messages for setpoint/actual value deviation 2 OFF delay / Set/act 2 t_OFF
p50380[0...n] Messages for overspeed threshold positive direction of rotation / Msg n_over pos
p50381[0...n] Messages for overspeed threshold negative direction of rotation / Msg n_over neg
p50388[0...n] Messages for setpoint/actual value deviation 1 threshold / Set/act 1 thresh
p50389[0...n] Messages for setpoint/actual value deviation 1 hysteresis / Set/act 1 hyst
p50390[0...n] Messages for setpoint/actual value deviation 1 OFF delay / Set/act t_OFF
p50394[0...n] Messages for field current threshold minimum threshold / Msg If min thresh
p50395[0...n] Messages for field current threshold minimum hysteresis / Msg If min hyst
p50396[0...n] Field current monitoring setpoint factor / If_mon set_fact
p50397[0...n] Field current monitoring fault delay time / If_mon F t_del
p50398[0...n] Messages for field current actual value less than setpoint fact / Msg If<set fact
p50399[0...n] Messages for field current actual value less than setpoint hyst / Msg If<set hyst
p50401[0...n] Fixed value 1 / Fix val 1