2 Parameters
2.3 Parameters for data sets
SINAMICS DCM
650 List Manual (LH8), 02/2015, 6RX1800-0ED76
p50190[0...n] Cl-loop arm current ctr prectr setpoint smoothing time constant / Ia prec set T
p50191[0...n] Cl-loop arm current ctr curr controller setp sm time constant / Ia ctr set T
p50192[0...n] Armature Alpha W limit control word / A Alpha W lim STW
p50200[0...n] Speed controller speed actual value smoothing time constant / n_ctr n_act T
p50201[0...n] Band-stop 1 resonant frequency / Band-st 1 f_n
p50202[0...n] Band-stop 1 quality / Band-st 1 quality
p50203[0...n] Band-stop 2 resonant frequency / Band-st 2 f_n
p50204[0...n] Band-stop 2 quality / Band-st 2 quality
p50205[0...n] Derivative-action element derivative-action time / D-act el t_d-act
p50206[0...n] Derivative-action element smoothing time / Der-act el t_DAE
p50208[0...n] Lead/lag element rate time / Lead/lag t_rate
p50209[0...n] Lead/lag element filter time / Lead/lag t_filter
p50220[0...n] Speed controller changeover PI/P speed setpoint threshold / PI/P n_set thresh
p50221[0...n] Speed controller changeover PI/P hysteresis / PI/P hyst
p50222[0...n] Speed controller changeover PI/P speed actual value threshold / PI/P n_act thresh
p50223[0...n] Speed controller pre-control enable / n_ctr prec ena
p50224[0...n] Speed controller integral component configuration / n_ctr I comp conf
p50225[0...n] Speed controller adaptation Kp y coordinate 2 / Adapt Kp y2
p50226[0...n] Speed controller adaptation Tn y coordinate 2 / Adapt Tn y2
p50228[0...n] Speed controller speed setpoint smoothing time constant / n_ctr n_set T
p50229[0...n] Mast/Sl drive ctr speed controller tracking I component / M/S drve ctr track
p50230[0...n] Set speed controller integral component duration / Set I_comp dur
p50234[0...n] Speed controller proportional component enable / n_ctr P_comp ena
p50237[0...n] Speed controller reference model natural frequency / n_ctrl ref_m fn
p50238[0...n] Speed controller reference model damping / n_ctrl ref_m d
p50239[0...n] Speed controller reference model dead time / n_ctr ref_m t_dead
p50240[0...n] Speed controller reference model activation / n_ctrl ref_m act
p50250[0...n] Field converter Alpha G limit / Field Alpha G lim
p50251[0...n] Field converter Alpha W limit / Field Alpha W lim
p50252[0...n] Field average number of line periods / Field line per no.
p50253[0...n] Field pre-control activation / Field prec act
p50254[0...n] Field current controller integral component activation / I_field_ctr I comp
p50255[0...n] Field current controller P gain / I_field ctr Kp
p50256[0...n] Field current controller integral time / I_field ctr Tn
p50257[0...n] Closed-loop field current control standstill field / If_ctr stst_field
p50258[0...n] Cl-loop field current control field current reduction delay time / If_ctr I_red t_del
p50260[0...n] Field current pre-control setpoint smoothing time constant / Field_prec set T
p50261[0...n] Field current controller setpoint smoothing time constant / I_field_ctr set T
p50263[0...n] Selection of motor flux input variable / Mot fl input sel
p50264[0...n] Field current controller proportional component activation / I_field_ctr P comp
p50273[0...n] EMF controller pre-control activation / EMF ctr prec act
p50274[0...n] EMF controller integral component activation / EMF ctr I comp act
p50275[0...n] EMF controller P gain / EMF ctr Kp
p50276[0...n] EMF controller integral time / EMF ctr Tn
p50277[0...n] EMF controller droop / EMF ctr droop
p50280[0...n] EMF controller pre-control setpoint smoothing time constant / EMF prec set T
p50281[0...n] EMF controller setpoint smoothing time constant / EMF ctr set T
p50282[0...n] EMF controller actual value smoothing time constant / EMF ctr act T
p50283[0...n] EMF controller pre-control actual value smoothing time constant / EMF prec act T
p50284[0...n] EMF controller proportional component activation / EMF ctr P comp act
p50285[0...n] EMF setpoint reduction line voltage smoothing time / EMF set line t_sm
p50286[0...n] EMF setpoint reduction line voltage upper limit / EMF set line upper
p50287[0...n] EMF setpoint reduction line voltage lower limit / EMF set line lower
p50288[0...n] EMF setpoint reduction evaluation factor / EMF set eval_fact
p50295[0...n] Transition rounding operating mode / RFG rounding mode