Output Channel for Axis 2
Name Value Internal
Value
Internal
Value, Type
Default Min. Max.
Output 1,
channel
configura-
tion
No function 0 BYTE No function
0x00
0 2
Slot Parameters for Axis 2
Name Value Internal
Value
Internal
Value, Type
Default Min. Max.
Output
mode
CW/CCW
Pulse/Direc-
tion
0
1
BYTE CW/CCW
0x00
0 1
Start fre-
quency *)
0...65535 0...65535 WORD 0
0x00
0 65535
*) Unit is Hz
GSD file:
Ext_User_Prm_Data_Len =
Ext_User_Prm_Data_Const(0) =
0x17
0x07, 0x27, 0x00, 0x13, 0x01\
0x00, 0x00, 0x00, 0x00, 0x00\
0x00, 0x00, 0x00, 0x00, 0x00\
0x00, 0x00, 0x00, 0x00, 0x00\
0x00, 0x00, 0x00;