1.6.1.1.5 Parameterization
The arrangement of the parameter data is performed with Automation Builder.
The parameter data directly influences the functionality of modules.
For non-standard applications, it is necessary to adapt the parameters to your system configu-
ration.
For programming, the library package PS552-MC-E is required. This library
package is not part of Automation Builder and has to be purchased separately.
Module Parameters
Name Value Internal
Value
Internal
Value, Type
Default Min. Max.
Module ID Internal 1830 WORD 0x0726 0 65535
Ignore
module
No
Yes
0
1
BYTE No
0x00
Parameter
length
Internal 19 BYTE 19 0 255
Check
Supply
Off
On
0
1
BYTE On
0x01
0 255
Input Channels for Axis 1
Name Value Internal
Value
Internal
Value, Type
Default Min. Max.
Input 0,
channel
configura-
tion
No function
Axis
enable /
limit switch
0
1
BYTE No function
0x00
0 1
Input 0,
input delay
0.1 ms
1 ms
8 ms
32 ms
0
1
2
3
BYTE 0.1 ms
0x00
0 3
Input 1,
channel
configura-
tion
No function
Stop
Registration
*)
0
1
2
BYTE No function
0x00
0 2
Input 1,
input delay
0.1 ms
1 ms
8 ms
32 ms
0
1
2
3
BYTE 0.1 ms
0x00
0 3
*) Reserved - do not use
Function Modules > S500-eCo