AOUT.VALUEU
General Information
Type R/W Parameter
Description Sets the analog output value.
Units V
Range –10 to +10 V
Default Value 0
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3470h/3 M_01-00-00-000
Modbus 32 (64-bit) M_01-03-00-000
Description
AOUT.VALUEU reads/writes the analog output value when AOUT.MODE = 0 (analog output signal is deter-
mined by the user).
Related Topics
10.5 Analog Output
AKD User Guide | AOUT Parameters