AOUT.VALUEU
General Information
Type R/W Parameter
Description Sets the analog output value.
Units V
Range –10 to +10 V
Default Value 0
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3470h/3 M_01-00-00-000
Modbus 32 (64-bit) M_01-03-00-000
Description
AOUT.VALUEU reads/writes the analog output value when AOUT.MODE = 0 (analog output signal is deter-
mined by the user).
Related Topics
10.5 Analog Output
AKD User Guide | AOUT Parameters
Kollmorgen | December 2010 289

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals