FB1.RESREFPHASE
General Information
Type NV Parameter
Description Sets the electrical degrees of phase lag in the resolver.
Units electrical degrees
Range -180 to 180°
Default Value -2°
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 308 M_01-03-00-000
Description
This parameter sets the electrical degrees of phase lag in the resolver.
See the motor resolver datasheet for the value for this parameter .
Related Topics
8.2 Feedback 1
AKD User Guide | FB1 Parameters
Kollmorgen | December 2010 413