FB1.RESREFPHASE
General Information
Type NV Parameter
Description Sets the electrical degrees of phase lag in the resolver.
Units electrical degrees
Range -180 to 180°
Default Value -
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 308 M_01-03-00-000
Description
This parameter sets the electrical degrees of phase lag in the resolver.
See the motor resolver datasheet for the value for this parameter .
Related Topics
8.2 Feedback 1
AKD User Guide | FB1 Parameters
Kollmorgen | December 2010 413

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing