AKD User Guide | DRV Parameters and Commands
DRV.HELP
General Information
Type R/O Parameter
Description
Reads the minimum, maximum, and default values for a specific param-
eter or command.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also N/A
Start Version M_01-00-00-000
Description
This parameter returns more information about a specific parameter or command.
In most cases, except special parameters, this command tells you the minimum, maximum, default, and actual
value of a parameter. Exceptions are commands that do not have these values (such as DRV.EN) or information
commands (such as DRV.VER).
Related Topics
16.1 Terminal
368 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing