AKD User Guide | VBUS Parameters
VBUS.RMSLIMIT
General Information
Type R/O Parameter
Description Reads the limit for the bus capacitors load.
Units Vrms
Range N/A
Default Value N/A
Data Type Integer
See Also N/A
Start Version M_00-00-55-000
Fieldbus Index/Subindex Object Start Version
Modbus 798 M_01-03-00-000
Description
This parameter reads the limit of the bus capacitor load. When the bus capacitor loads exceeds this limit, the
drive generates fault F503.
Excessive bus capacitor load may indicate a disconnected main supply phase.
Related Topics
7.2 Regeneration
616 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals