AKD User Guide | IL Parameters
IL.LIMITP
General Information
Type NV Parameter
Description Sets the positive user (application-specific) current limit.
Units A
Range 0 A to drive peak current (DRV.IPEAK)
Default Value Drive peak current (DRV.IPEAK)
Data Type Float
See Also IL.LIMITN
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
356Eh/0 M_01-00-00-000
Modbus 462 M_01-03-00-000
Description
This parameter sets the positive user limit clamp value of the torque-producing q-component current command
(IL.CMD ). The current command is additionally limited by the motor peak current setting (MOTOR.IPEAK) and
by the present value of the foldback I²t peak motor current protection.
Related Topics
11.3 Current Loop
478 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz