AKD User Guide | MT Parameters and Commands
MT.MTNEXT
General Information
Type R/W Parameter
Description
Specifies following motion task number; active in opmode 2 (position)
only.
Units N/A
Range 0 to 128
Default Value 0
Data Type Integer
See Also
MT.NUM , MT.P, MT.V, MT.CNTL, MT.ACC, MT.DEC, MT.TNUM,
MT.TNEXT, MT.SET , MT.LOAD
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
35BCh/0 M_01-00-00-000
Modbus 546 M_01-03-00-000
Description
MT.MTNEXT specifies the number of the following motion task and is used by the MT.SET and MT.LOAD com-
mand. This parameter is a temporary value. A motion task is only set after an MT.SET command.
The motion task control word can be selected so that a following motion task is executed after a first motion task.
This parameter displays which motion task should be started after the first motion task.
Related Topics
12.2 Motion Tasks
526 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing