EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #412 background imageLoading...
Page #412 background image
AKD User Guide | FB1 Parameters
FB1.RESKTR
General Information
Type NV Parameter
Description Sets the resolver nominal transformation ratio.
Units N/A
Range 0.001 to 50.000
Default Value 0.5
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 306 M_01-03-00-000
Description
This parameter sets the resolver nominal transformation ratio. It affects the resolver excitation output amplitude.
The value can be obtained from the resolver data sheet.
Related Topics
8.2 Feedback 1
412 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals