EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #549 background imageLoading...
Page #549 background image
PL.MODP1
General Information
Type R/W parameter
Description Sets modulo range parameter.
Units Depends on UNIT.PROTARY and UNIT.PLINEAR
Range N/A
Default Value N/A
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3637h/0 M_01-00-00-000
Modbus 606 (64-bit) M_01-03-00-000
Description
This parameter is either the beginning or the end of the modulo range, depending on whether this value is smaller
or larger than PL.MODP2. If you set PL.MODP1 equal to PL.MODP2, an error message occurs.
Condition Beginning of the modulo-range End of the modulo-range
PL.MODP1 < PL.MODP2 PL.MODP1 PL.MODP2
PL.MODP2 < PL.MODP1 PL.MODP2 PL.MODP1
Related Topics
11.5 Position Loop
AKD User Guide | PL Parameters
Kollmorgen | December 2010 549

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing