REC.TRIGVAL
General Information
Type R/W Parameter
Description Sets the trigger value.
Units The units of the parameter are chosen according to the unit type.
Range 0 to 2
Default Value 0
Data Type Integer
See Also
REC.TRIG, REC.TRIGPARAM, REC.TRIGVAL, REC.TRIGSLOPE,
REC.TRIGPOS
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 730 (64-bit) M_01-03-00-000
Description
REC.TRIGVAL is the value that must be met by REC.TRIGPARAM for the trigger to occur. The units of this
parameter are set according to the units of REC.TRIGPARAM.
Related Topics
15 Scope
AKD User Guide | REC Parameters and Commands
Kollmorgen | December 2010 583

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing