EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #606 background imageLoading...
Page #606 background image
AKD User Guide | UNIT Parameters
UNIT.ACCROTARY
General Information
Type NV Parameter
Description Sets the rotary acceleration/deceleration units.
Units rpm/s, rps/s, deg/s
2
, [PIN/POUT]/s
2
Range 0 to 3
Default Value 0 rpm/s
Data Type Integer
See Also DRV.ACC, "DRV.DEC" (=> p. 351), MOTOR.TYPE
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3659h/0 M_01-00-00-000
Modbus 778 M_01-03-00-000
Description
UNIT.ACCROTARY sets the acceleration/deceleration units when the motor type (MOTOR.TYPE) is rotary.
Type Description
0 rpm/s
1 rps/s
2 deg/s
2
3 (PIN/POUT)/s
2
Related Topics
9 Selecting Units for Your Application
606 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals