EasyManua.ls Logo

Kollmorgen AKD series

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD User Guide | DRV Parameters and Commands
DRV.DISSOURCES
General Information
Type R/O Parameter
Description Returns the possible reason for a drive disable.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also DRV.ACTIVE, DRV.FAULTS, DRV.EN, DRV.DIS
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 240 M_01-03-00-000
Description
DRV.DISSOURCES is a bitwise parameter that returns the status of possible causes of a drive disable. If this
parameter is 0, then the drive is enabled.
The return value specific bits are as follows:
Bit Status and Response
0 Software disable (execute DRV.EN to issue software enable)
1 Fault exists (read DRV.FAULTS to get the active faults)
2 Hardware disable (remote enable input is low)
3 In-rush disable (the in-rush relay is opened)
4 Initialization disable (the drive did not finish the initialization process)
5 Controlled stop disable from a digital input.
Related Topics
10.10 Controlled Stop
356 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Related product manuals