EasyManuals Logo

Kollmorgen AKD series User Manual

Kollmorgen AKD series
906 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #296 background imageLoading...
Page #296 background image
AKD User Guide | BODE Parameters
BODE.INJECTPOINT
General Information
Type R/W Parameter
Description Sets whether the excitation uses current or velocity excitation type.
Units N/A
Range 0 to 2
Default Value 0
Data Type Integer
See Also BODE.IAMP, BODE.MODE, BODE.VAMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 44 M_01-03-00-000
Description
BODE.INJECTPOINT sets whether the excitation uses current or velocity excitation type.
BODE.INJECTPOINT Description
0 None
1 Current
2 Velocity
Example
Set BODE.INJECTPOINT to current:
-->BODE.INJECTPOINT 1
Get BODE.INJECTPOINT (already set to current):
-->BODE.INJECTPOINT 1
Related Topics
14.3 Using the Autotuner
14.3.4 Using the Autotuner: Advanced
15 Scope
1.2.1.5 Bode (set command source)
6.5 Settings
126
Error: Invalid Bode plot mode for this function. and others)
296 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing