AKD User Guide | BODE Parameters
BODE.INJECTPOINT
General Information
Type R/W Parameter
Description Sets whether the excitation uses current or velocity excitation type.
Units N/A
Range 0 to 2
Default Value 0
Data Type Integer
See Also BODE.IAMP, BODE.MODE, BODE.VAMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 44 M_01-03-00-000
Description
BODE.INJECTPOINT sets whether the excitation uses current or velocity excitation type.
BODE.INJECTPOINT Description
0 None
1 Current
2 Velocity
Example
Set BODE.INJECTPOINT to current:
-->BODE.INJECTPOINT 1
Get BODE.INJECTPOINT (already set to current):
-->BODE.INJECTPOINT 1