AKD User Guide | PL Parameters
PL.MODP2
General Information
Type R/W Parameter
Description Sets the beginning or end modulo range parameter.
Units Depends on UNIT.PROTARY and UNIT.PLINEAR.
Range N/A
Default Value N/A
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE
and CANopen
3638h/0 M_01-00-00-000
Modbus 610 (64-bit) M_01-03-00-000
Description
This parameter is either the beginning or the end of the modulo range, depending on whether this value is smaller
or larger than PL.MODP1.
Condition
Beginning of the modulo
range
End of the modulo range
PL.MODP1 < PL.MODP2 PL.MODP1 PL.MODP2
PL.MODP2 < PL.MODP1 PL.MODP2 PL.MODP1