AKD User Guide | DRV Parameters and Commands
DRV.MEMDATA
General Information
Type R/W Parameter
Description Sets or reads a value from an internal address.
Units N/A
Range N/A
Default Value N/A
Data Type N/A
See Also DRV.MEMADDR
Start Version M_01-00-00-000
Description
DRV.MEMDATA reads a value from the address that was set by DRV.MEMADDR or writes a value to this
address. The input value can be either decimal or hexadecimal with 0x prefix.
Examples
Read a value from internal address:
-->DRV.MEMDATA 01
Write a hexadecimal value to an internal address:
-->DRV.MEMADDR 0x01
378 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing